Basic knowledge of electricity consumption of new amusement equipment
The grounding type of the low-voltage distribution system of the amusement equipment shall adopt tn-s system;
Electrical equipment metal shell and no live metal structure must be reliably grounded; The protection repeated
grounding resistance of low-voltage distribution system shall not exceed 10 euros;
We all know that children's amusement equipment and new amusement equipment can be
started normally only when the electricity is on. Especially for some large amusement
equipment, what details should be paid attention to when the electricity is on? We're going to
popularize it today.
The design function of the electrical system of amusement equipment must meet
the needs of operation control and safety protection of the amusement equipment,
and meet the requirements of normal use under local environmental conditions.
The grounding type of the low-voltage distribution system of the amusement
equipment shall adopt tn-s system; Electrical equipment metal shell and no live
metal structure must be reliably grounded; The protection repeated grounding
resistance of low-voltage distribution system shall not exceed 10 euros; The
design and construction of grounding device shall comply with the provisions
of "code for grounding design of industrial and civil electric devices". The insulation
resistance between the live circuit and the ground shall be no less than 1M ohm.
Amusement facilities over 15m in height should be equipped with lightning
protection device, which must be connected reliably and its grounding
resistance should not be more than 10 euros.
Amusement equipment should not be installed in the high-voltage overhead
transmission and distribution line channel, if the installation must obtain
the consent of the local power management department.